Signal Review
Part six of six. Sanger's chemistry, the capillary machines that ran it, and what the finished sequence changed
The instrument that read the human genome was not one machine but a hall of them, running a chemistry invented in 1977 at a scale nobody had tried. The project finished in April 2003, two years early, and the cost of doing it again has since fallen by a factor of a million.
The Human Genome Project was the international effort, formally begun in October 1990 and declared complete in April 2003, to determine the sequence of the roughly 3 billion base pairs of human DNA.
It was coordinated by the US National Institutes of Health and Department of Energy with the Wellcome Trust in Britain, and its sequencing was done at 20 centres in six countries, most of it at five: the Whitehead Institute in Massachusetts, Washington University in St Louis, Baylor College of Medicine in Houston, the Joint Genome Institute in California, and the Sanger Centre at Hinxton near Cambridge, shown in the photograph, which read about a third of the total. The project's cost, in the NIH's accounting, was about 2.7 billion dollars over 13 years.
The chemistry was Sanger sequencing, devised by Frederick Sanger at Cambridge and published in 1977, for which he received his second Nobel Prize in Chemistry in 1980. A DNA polymerase copies the strand to be read, but the reaction includes a small fraction of modified building blocks, dideoxynucleotides, that stop the copy wherever they are incorporated. The result is a set of fragments of every possible length, each ending at a known letter. Sorted by size, they spell out the sequence. The project's innovation was scale and automation. By the late 1990s the fragments were labelled with four fluorescent dyes, one per letter, and sorted by electrophoresis through capillaries, hair-thin glass tubes, in machines that read the colour of each fragment as it passed a laser. The Applied Biosystems 3700, introduced in 1998 with 96 capillaries, could read about 500 letters from each of several hundred samples a day; the large centres ran a hundred or more of them around the clock, fed by robots that prepared the samples.
Each stretch of the genome was read about eight to ten times over, in overlapping fragments, to reach the finishing standard of fewer than one error in 10,000 letters. The public project worked chromosome by chromosome from mapped clones; the private company Celera, which announced a rival effort in 1998, shot the whole genome into random fragments and reassembled them by computer, and the two published draft sequences side by side, in *Nature* and *Science*, in February 2001.
The first surprise was the count. The finished sequence contained about 20,000 protein-coding genes, fewer than the 100,000 that had been widely expected and not many more than a roundworm's. Less than 2 per cent of the genome codes for protein; much of the rest turned out to regulate when and where those genes are used. The sequence gave medicine a reference against which any individual's variation could be read, which made possible the mapping of thousands of disease-associated variants in the following decade, and it gave biology a parts list for every cell.
The instruments did not stand still. The sequencing-by-synthesis machines that replaced capillary sequencers after 2006 read millions of fragments at once, and the NIH's National Human Genome Research Institute, which has tracked the cost since 2001, reported the price of a human genome falling from about 100 million dollars then to under 1,000 dollars by 2020. The last gaps in the reference, the repetitive stretches the original methods could not cross, were closed by the Telomere-to-Telomere consortium in 2022, using long-read machines that read tens of thousands of letters in a single pass.
With Sanger sequencing at industrial scale. Fragments ending at known letters were labelled with four fluorescent dyes and sorted by size in hair-thin capillaries while a laser read their colours, and each stretch was read eight to ten times over to reach fewer than one error in 10,000 letters.
It formally began in October 1990 and was declared complete in April 2003, and it cost about 2.7 billion dollars over 13 years in the accounting of the US National Institutes of Health.
The finished sequence contained about 20,000 protein-coding genes, fewer than the 100,000 that had been widely expected and not many more than a roundworm's. Less than 2 per cent of the genome codes for protein.
The National Human Genome Research Institute, which has tracked the cost since 2001, reported the price of a human genome falling from about 100 million dollars then to under 1,000 dollars by 2020, as sequencing-by-synthesis machines replaced capillary sequencers.